{"title":"G12 lamps","description":"\u003cp\u003e Lumenled offers high-quality G12 lamps that replace discharge, metal halide and halogen lamps in an energy-efficient manner. G12 lamps are suitable for industrial, street lighting and everyday environments. Choose according to the amount of lumen, color temperature and efficiency class. We deliver quickly from Jyväskylä to all of Finland and support you with expertise in project selection.\u003c\/p\u003e","products":[{"product_id":"90v-35w-3200lm-cmh-single-ended-g12-4200k-monimetallilamppu-tungsram","title":"35W, 3200lm CMH Single Ended G12, 4200K Metal-halide lamp","description":"\u003cdiv\u003eProduct code: \u003cspan data-mce-fragment=\"1\"\u003e93095374\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDiameter 14.5mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLength 90mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLumen 3200lm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLight efficiency 91lm\/W\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eColour rendering index CRI 88+\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eColor temperature 4200K\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eG12 base \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUsage life 12,000h\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnergy class G\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tungsram","offers":[{"title":"35W \/ 4200K \/ G12","offer_id":42529162658005,"sku":"4884612","price":46.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/products\/SE_837d1a46-593d-49b8-b024-fd32d8b93dd5.png?v=1633684940"},{"product_id":"80-100v-70w-6000lm-g12-3000k-22-5x90mm-monimetallilamppu-thorgeon","title":"80-100V, 70W, 6000lm, G12, 3000K, 22.5x90mm, Metal Halide Lamp Thorgeon","description":"\u003cp\u003e\u003cstrong\u003eProduct code: 4752280005621\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLamp features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp wattage:\u003c\/strong\u003e 70 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp voltage:\u003c\/strong\u003e 80–100 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLuminous flux:\u003c\/strong\u003e 6000 lm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp base:\u003c\/strong\u003e G12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor rendering index:\u003c\/strong\u003e CRI 60–69\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor temperature:\u003c\/strong\u003e 3000 K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLuminous efficacy of lamp:\u003c\/strong\u003e 66.6 lm\/W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp shape:\u003c\/strong\u003e Tubular, single-ended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter:\u003c\/strong\u003e 22.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall length:\u003c\/strong\u003e 90 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal ignitor required:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Clear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp designation:\u003c\/strong\u003e T6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thorgeon","offers":[{"title":"70W \/ 3000K \/ G12","offer_id":54789724373336,"sku":"4752280005621","price":35.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/43a23cb7ebd69c74d936426d7cdd8157792695a9.png?v=1745845069"},{"product_id":"85v-35w-3500lm-cm-t-360-g12-3000k-monimetallilamppu","title":"85V, 35W, 3500lm, CM-T 360°, G12, 3000K Metal halide lamp","description":"\u003ch2\u003e\u003cstrong\u003eOrder product\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cstrong\u003eDelivery time about 1-1½ weeks\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct code: 145919\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLamp features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter: \u003c\/strong\u003e20mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 100mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLuminous flux:\u003c\/strong\u003e 3500lm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor rendering index CRI:\u003c\/strong\u003e 80-89\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor temperature: \u003c\/strong\u003e3000K\u003c\/li\u003e\n\u003cli\u003eG12 base \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifespan:\u003c\/strong\u003e 10,000h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy class:\u003c\/strong\u003e F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lumenled Oy","offers":[{"title":"35W \/ 3000K \/ Grade 12","offer_id":54835110838616,"sku":"145919","price":40.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/images_3.jpg?v=1746600661"},{"product_id":"monimetallilamppu-g12-70w-3000k-cm-t","title":"Metal halide lamp G12 70W 6500lm 3000K 360° UV-protected – 20x100mm, for professional use","description":"\u003cp\u003eThe G12 metal halide lamp is an efficient lamp based on discharge technology, used for professional and industrial lighting. A power of 70 W achieves 6500 lm of light — significantly more than a halogen or old fluorescent lamp at the same power. The 3000 K color temperature provides a warm white tone, and the 360° light distribution spreads light in every direction. The UV-protected bulb ensures safe use in locations where the lighting is close to the objects being illuminated.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRequires a separate ballast. 85 V lamp voltage — NOT for direct 230 V mains voltage. G12 base. Installation by a qualified electrician.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"product-notice product-notice--warning\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e⚠ Made-to-order product\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDelivery time approximately \u003cstrong\u003e1–1½ weeks\u003c\/strong\u003e from the order. Availability can be checked in the shopping cart.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eProduct type: metal halide lamp\u003c\/li\u003e\n\n\u003cli\u003eSeries: CM-T 360° (compact metal halide)\u003c\/li\u003e\n\n\u003cli\u003eBase: G12\u003c\/li\u003e\n\n\u003cli\u003ePower: 70 W\u003c\/li\u003e\n\n\u003cli\u003eLuminous flux: 6500 lm\u003c\/li\u003e\n\n\u003cli\u003eLuminous efficacy: 93 lm\/W\u003c\/li\u003e\n\n\u003cli\u003eColor temperature: 3000 K (warm white)\u003c\/li\u003e\n\n\u003cli\u003eColor rendering index (CRI): 80–89\u003c\/li\u003e\n\n\u003cli\u003eLight distribution: 360° (omnidirectional)\u003c\/li\u003e\n\n\u003cli\u003eLamp voltage: \u003cstrong\u003e85 V\u003c\/strong\u003e (requires a ballast)\u003c\/li\u003e\n\n\u003cli\u003eUV protection: yes\u003c\/li\u003e\n\n\u003cli\u003eDimensions: Ø 20 × 100 mm\u003c\/li\u003e\n\n\u003cli\u003eProduct code: 145921\u003c\/li\u003e\n\n\u003cli\u003eEAN: 8714681459218\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and installation\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eBallast required — no direct mains connection\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe metal halide lamp does NOT work directly on 230 V mains voltage. The lamp requires a separate ballast that:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eRegulates the lamp's starting and operating voltage (the lamp operates at 85 V)\u003c\/li\u003e\n\n\u003cli\u003eProvides a high starting voltage to ignite the lamp\u003c\/li\u003e\n\n\u003cli\u003eStabilizes the current during operation\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003eThe ballast can be magnetic (older, traditional choke + igniter) or electronic (modern HID driver — better control, less flickering). Check your luminaire's ballast before purchasing. An electrician will take care of choosing the correct type.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eIndustrial halls and warehouses\u003c\/li\u003e\n\n\u003cli\u003eSports halls and multi-purpose facilities\u003c\/li\u003e\n\n\u003cli\u003eGeneral lighting for commercial premises\u003c\/li\u003e\n\n\u003cli\u003eHigh-ceiling lighting solutions\u003c\/li\u003e\n\n\u003cli\u003eOutdoor locations where bright light is needed (in a suitably IP-rated luminaire)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eStartup and shutdown time\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA special feature of the metal halide lamp is its slow startup and shutdown:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eStartup to full brightness:\u003c\/strong\u003e 1–4 minutes (from cold)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRestart after a short shutdown:\u003c\/strong\u003e 5–10 minutes waiting time\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003eThis limits the use of the lamp — it is not suitable for locations where light is needed immediately or where the lamp is switched on\/off frequently. It is well-suited for locations where the light is on for the entire duration of opening hours or a work shift.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eUV protection\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide lamp inherently produces a significant amount of UV radiation. The UV-protected bulb filters out harmful UV. This is especially important in environments where people are close to the light or materials that can fade. Never use a metal halide lamp without a luminaire equipped with protective glass — even a UV-protected lamp requires a protective cover in the luminaire.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe typical service life of a metal halide lamp is 6,000–10,000 hours — significantly more than halogen but less than LED. For long-term use, LED is often a more reasonable long-term solution.\u003c\/p\u003e\n\n\u003c\/details\u003e","brand":"Lumenled Oy","offers":[{"title":"70W","offer_id":55904027017560,"sku":"145921","price":40.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/145921.webp?v=1759836991"},{"product_id":"thorgeon-monimetallilamppu-g12-35w-3000k","title":"Thorgeon multi-metal lamp G12 35W 2200lm 3000K – HID, warm white","description":"\u003cp\u003eThe Thorgeon metal halide lamp is the smallest power class Thorgeon HID gas discharge lamp, producing 2,200 lumens of light output with a warm 3000K color temperature. The 3000K hue is rare in the 35W metal halide category – especially suitable for display case lighting, ambient lighting in small shops, restaurants, and for maintaining vintage luminaires. Requires an external HID ballast and ignitor – does not work directly with mains voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG12 base. Requires an external HID ballast + ignitor (35W rating). Start-up time 1–4 minutes, re-ignition requires cooling.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp type: Metal halide lamp (HID, Metal Halide gas discharge lamp)\u003c\/li\u003e\n  \u003cli\u003eBrand: Thorgeon\u003c\/li\u003e\n  \u003cli\u003eBase: G12 (bi-pin)\u003c\/li\u003e\n  \u003cli\u003ePower: 35 W\u003c\/li\u003e\n  \u003cli\u003eLamp operating voltage: \u003cstrong\u003e75–95 V\u003c\/strong\u003e (internal discharge voltage – not mains voltage)\u003c\/li\u003e\n  \u003cli\u003eLuminous flux: \u003cstrong\u003e2,200 lm\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor temperature: \u003cstrong\u003e3000 K (warm white – rare in MH category)\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor rendering index (CRI): 60–69\u003c\/li\u003e\n  \u003cli\u003eLuminous efficacy: 62.8 lm\/W\u003c\/li\u003e\n  \u003cli\u003eLamp shape: tubular, single-ended (clear glass)\u003c\/li\u003e\n  \u003cli\u003eLamp designation: T6 (diameter 22.5 mm)\u003c\/li\u003e\n  \u003cli\u003eExternal ballast required: Yes (HID ballast + ignitor)\u003c\/li\u003e\n  \u003cli\u003eDiameter: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003eTotal length: 90 mm\u003c\/li\u003e\n  \u003cli\u003eProduct code (EAN): 4752280005607\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and installation\u003c\/strong\u003e\u003c\/summary\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is a metal halide lamp?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide (MH) lamp is a gas discharge lamp that produces strong and uniform light by combining high-pressure mercury with metal halides. This gives the lamp:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGood light output from a small size\u003c\/strong\u003e – 2,200 lm from a Ø22.5 × 90 mm lamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarm color temperature\u003c\/strong\u003e – 3000 K (incandescent-like, rare in MH category)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral lighting color rendering\u003c\/strong\u003e – CRI 60–69 (suitable for ambient lighting, not for applications requiring precise color rendering)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e3000K – warm hue for small spaces\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMost metal halide lamps are produced with cooler hues (4000K, 4200K), as their gas discharge spectrum naturally produces cooler light. A 3000K warm white MH lamp is a \u003cstrong\u003especial product\u003c\/strong\u003e, particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay case lighting\u003c\/strong\u003e – clothing stores, jewelry stores, interior design shops where a warm hue accentuates products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmaller restaurants and cafes\u003c\/strong\u003e – accent lighting in spotlights\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHotel lobbies\u003c\/strong\u003e – warm spot lighting in smaller spaces\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVintage luminaires\u003c\/strong\u003e – maintaining older spotlights with an incandescent-like hue\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintaining existing 3000K MH systems\u003c\/strong\u003e – if the old lamp was 3000K, switching to a cooler hue would significantly alter the ambiance of the space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need a neutral white hue for general lighting, check out the \u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-35w-4200k\"\u003e4200K model\u003c\/a\u003e – the same Thorgeon product, but with a 4200K neutral white hue.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e35W – lowest power class, for special use\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e35W is the lowest common power class for metal halide lamps. Typical applications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay case lighting and exhibition spaces\u003c\/strong\u003e – lower luminous efficacy is sufficient for close-range lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpotlights\u003c\/strong\u003e – in small shops where the lamp is used close to the product\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmaller advertising luminaires\u003c\/strong\u003e – for 5–20 m² advertisements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBollard luminaires\u003c\/strong\u003e – low poles (1–3 m), such as garden spotlights\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need more luminous efficacy for a larger space with a warm hue, check out the \u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-150w-3000k\"\u003e150W 3000K model\u003c\/a\u003e (12,500 lm).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eExternal ballast and ignitor required\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis lamp \u003cstrong\u003edoes not work directly with mains voltage\u003c\/strong\u003e – it requires an external HID ballast and ignitor. Important notes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThe internal lamp voltage is 75–95 V (lower than the 80–100 V of larger MH lamps)\u003c\/li\u003e\n  \u003cli\u003eThe ballast must be rated for a \u003cstrong\u003e35W metal halide lamp\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eAn ignitor is needed to start the lamp\u003c\/li\u003e\n  \u003cli\u003eInstallation requires the expertise of an electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eYou can find compatible ballasts in the \u003ca href=\"\/en\/collections\/liitantalaitteet-kuristimet\"\u003eElectrical Supplies → Ballasts\/Chokes\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStart-up time and cool-down period\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eHID lamps behave differently from LED and fluorescent lamps:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStart-up time to full power:\u003c\/strong\u003e approximately 1–4 minutes after switching on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-ignition after power outage:\u003c\/strong\u003e requires a 5–20 minute cool-down period – a hot lamp cannot be re-ignited immediately\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuring lifetime:\u003c\/strong\u003e color temperature may shift slightly and light level may decrease (typical HID phenomenon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eHID lamps are best suited for spaces where lighting is on for long periods and short on\/off cycles are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCRI 60–69 – for ambient lighting\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe color rendering index (CRI 60–69) of this lamp is suitable for ambient lighting, but color differences will not be precisely distinguished. However, the warmth of the 3000K hue combined with a CRI of 60–69 provides a \u003cstrong\u003epleasant ambient light\u003c\/strong\u003e that does not require precise color rendering.\u003c\/p\u003e\n\n\u003cp\u003eFor applications where color accuracy is important (e.g., clothing stores with color-coordinated product displays, museums, photography workshops), consider an LED alternative (LEDs achieve CRI 80–95+).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLED alternative – small power class, easy transition\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor MH lamps in smaller power classes (35W and below), an \u003cstrong\u003eLED replacement is particularly sensible\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThe LED selection is wider\u003c\/strong\u003e in small power classes – several brands available\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBetter value for money\u003c\/strong\u003e – LED lamps are often cheaper than MH lamps with the same light output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLonger lifespan\u003c\/strong\u003e – LED 50,000+ h vs MH 6,000–15,000 h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower energy consumption\u003c\/strong\u003e – LED produces the same luminous efficacy with approximately 12–18W of power\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3000K LED alternatives are widely available\u003c\/strong\u003e – unlike MH lamps, where 3000K is rare\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eExplore our selection in the \u003ca href=\"\/en\/collections\/g12-led-lamput\"\u003eG12 LED lamps\u003c\/a\u003e category. However, this Thorgeon MH lamp is suitable for maintaining existing 35W systems when the luminaire and ballast are precisely dimensioned for MH technology.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety precautions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse the lamp only in a suitable enclosed luminaire – due to UV radiation, open installation can be dangerous\u003c\/li\u003e\n  \u003cli\u003eDo not touch a hot lamp\u003c\/li\u003e\n  \u003cli\u003eIf the lamp breaks, act carefully – it contains a small amount of mercury\u003c\/li\u003e\n  \u003cli\u003eAt the end of its life, recycle in accordance with the WEEE directive at an SER collection point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eCheck that the luminaire has a G12 base and is designed for a 35W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eCheck that an external HID ballast and ignitor are used (\u003cstrong\u003e35W MH\u003c\/strong\u003e rating)\u003c\/li\u003e\n  \u003cli\u003eTurn off power at the main switch\u003c\/li\u003e\n  \u003cli\u003eInstall the lamp – do not touch the glass with your fingers (grease can cause a hot spot)\u003c\/li\u003e\n  \u003cli\u003eTurn on the power\u003c\/li\u003e\n  \u003cli\u003eWait 1–4 minutes for full power to be reached\u003c\/li\u003e\n  \u003cli\u003eCheck that the lamp burns steadily without flickering\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eAlso, explore other \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003emetal halide lamps\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/g12-led-lamput\"\u003eG12 LED alternatives\u003c\/a\u003e in our selection.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Thorgeon","offers":[{"title":"35W \/ 3000K \/ Grade 12","offer_id":57268633469272,"sku":"4752280005607","price":35.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/1be87fbfd83b05a5e036d25d4cb84045a14e4f74.png?v=1778507760"},{"product_id":"thorgeon-monimetallilamppu-g12-35w-4200k","title":"Thorgeon Metal Halide Lamp G12 35W 2200lm 4200K – HID, T6 tube","description":"\u003cp\u003eThe Thorgeon metal halide lamp is the smallest power class Thorgeon HID gas discharge lamp, producing a luminous flux of 2,200 lumens with a 4200 K neutral white color. Suitable for display case lighting, small advertising luminaires, spot lighting in small shops, and maintenance of older 35W systems. Requires an external HID ballast and ignitor – does not work directly with mains voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG12 base. Requires an external HID ballast + ignitor (35W rating). Ignition time 1–4 minutes, re-ignition requires cooling.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp type: Metal halide lamp (HID, Metal Halide gas discharge lamp)\u003c\/li\u003e\n  \u003cli\u003eBrand: Thorgeon\u003c\/li\u003e\n  \u003cli\u003eBase: G12 (bi-pin)\u003c\/li\u003e\n  \u003cli\u003ePower: 35 W\u003c\/li\u003e\n  \u003cli\u003eLamp operating voltage: \u003cstrong\u003e75–95 V\u003c\/strong\u003e (internal discharge voltage – not mains voltage)\u003c\/li\u003e\n  \u003cli\u003eLuminous flux: \u003cstrong\u003e2,200 lm\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor temperature: 4200 K (neutral white)\u003c\/li\u003e\n  \u003cli\u003eColor rendering index (CRI): 60–69\u003c\/li\u003e\n  \u003cli\u003eLuminous efficacy: 62.8 lm\/W\u003c\/li\u003e\n  \u003cli\u003eLamp shape: Tubular, single-ended (clear glass)\u003c\/li\u003e\n  \u003cli\u003eLamp designation: T6 (diameter 22.5 mm)\u003c\/li\u003e\n  \u003cli\u003eExternal ballast required: Yes (HID ballast + ignitor)\u003c\/li\u003e\n  \u003cli\u003eDiameter: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003eTotal length: 90 mm\u003c\/li\u003e\n  \u003cli\u003eProduct code (EAN): 4752280005614\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and installation\u003c\/strong\u003e\u003c\/summary\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is a metal halide lamp?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide (MH) lamp is a gas-discharge lamp that produces intense and stable light by combining high-pressure mercury with metal halides. This gives the lamp:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGood light output from a small size\u003c\/strong\u003e – 2,200 lm from a Ø22.5 × 90 mm lamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeutral color temperature\u003c\/strong\u003e – 4200 K (natural white)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral lighting color rendering\u003c\/strong\u003e – CRI 60–69 (suitable for general lighting, not color accuracy)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e35W – lowest power class, for special use\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e35W is the lowest common power class for metal halide lamps. Typical applications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay case luminaires and exhibition spaces\u003c\/strong\u003e – lower luminous efficacy is sufficient for close-range lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpotlights\u003c\/strong\u003e – in small shops where the lamp is used close to the product\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmaller advertising luminaires\u003c\/strong\u003e – for 5–20 m² advertisements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBollard lights\u003c\/strong\u003e – low poles (1–3 m)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance of existing 35W systems\u003c\/strong\u003e – when the ballast rating is 35W\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need more light output for a larger space, check out our selection:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-70w-4200k\"\u003eThorgeon 70W G12 4200K\u003c\/a\u003e (6,000 lm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-150w-4200k\"\u003eThorgeon 150W G12 4200K\u003c\/a\u003e (12,500 lm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eExternal ballast and ignitor required\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis lamp \u003cstrong\u003edoes not work directly with mains voltage\u003c\/strong\u003e – it requires an external HID ballast and ignitor. Important notes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThe internal lamp voltage is 75–95 V (lower than 80–100 V for larger MH lamps)\u003c\/li\u003e\n  \u003cli\u003eThe ballast must be rated for a \u003cstrong\u003e35W metal halide lamp\u003c\/strong\u003e (not 70W or 150W)\u003c\/li\u003e\n  \u003cli\u003eAn ignitor is needed to start the lamp\u003c\/li\u003e\n  \u003cli\u003eInstallation requires the expertise of an electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompatible ballasts can be found in the \u003ca href=\"\/en\/collections\/liitantalaitteet-kuristimet\"\u003eElectrical Supplies → Ballasts\/Chokes\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIgnition time and cool-down period\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe behavior of HID lamps differs from LED and fluorescent lamps:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition time to full power:\u003c\/strong\u003e approximately 1–4 minutes after switching on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-ignition after power failure:\u003c\/strong\u003e requires 5–20 minutes of cooling – a hot lamp cannot be re-ignited immediately\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuring lifetime:\u003c\/strong\u003e color temperature may shift slightly and light level may decrease (typical HID phenomenon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eHID lamps are best suited for spaces where lighting is on for long periods and short on\/off cycles are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCRI 60–69 – for general lighting, not for color accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe color rendering index (CRI 60–69) of this lamp is suitable for general lighting, but color differences are not precisely distinguishable. For example, the colors of clothes, jewelry, and paints may appear different compared to natural light. Not suitable for retail lighting where color accuracy is important – clothing stores, jewelry stores, exhibition spaces.\u003c\/p\u003e\n\n\u003cp\u003eFor applications requiring precise color rendering, consider an LED alternative (LEDs achieve CRI 80–95+).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLED alternative – low power class, easy transition\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor lower power class (35W and below) MH lamps, an \u003cstrong\u003eLED replacement is particularly sensible\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED selection is wider\u003c\/strong\u003e in low power classes – several brands available\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBetter value for money\u003c\/strong\u003e – LED lamps are often cheaper than MH lamps with the same light output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLonger lifespan\u003c\/strong\u003e – LED 50,000+ h vs MH 6,000–15,000 h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower energy consumption\u003c\/strong\u003e – LED produces the same light efficacy with approximately 12–18W of power\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eExplore our selection in the \u003ca href=\"\/en\/collections\/g12-led-lamput\"\u003eG12 LED lamps\u003c\/a\u003e category – options are available in several power classes. However, this Thorgeon MH lamp is suitable for maintaining existing 35W systems when the luminaire and ballast are precisely dimensioned for MH technology.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse the lamp only in a suitable enclosed luminaire – due to UV radiation, open installation can be dangerous\u003c\/li\u003e\n  \u003cli\u003eDo not touch a hot lamp\u003c\/li\u003e\n  \u003cli\u003eIf the lamp breaks, act carefully – it contains a small amount of mercury\u003c\/li\u003e\n  \u003cli\u003eAt the end of its life, recycle in accordance with the WEEE directive at an authorized collection point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eCheck that the luminaire has a G12 base and is designed for a 35W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eCheck that an external HID ballast and ignitor are used (\u003cstrong\u003e35W MH\u003c\/strong\u003e rating)\u003c\/li\u003e\n  \u003cli\u003eTurn off the power at the main switch\u003c\/li\u003e\n  \u003cli\u003eInstall the lamp – do not touch the glass with your fingers (grease can cause a hot spot)\u003c\/li\u003e\n  \u003cli\u003eTurn on the power\u003c\/li\u003e\n  \u003cli\u003eWait 1–4 minutes for full power to be reached\u003c\/li\u003e\n  \u003cli\u003eCheck that the lamp is burning steadily without flickering\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eAlso explore our selection of \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003eother metal halide lamps\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/g12-led-lamput\"\u003eG12 LED alternatives\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Thorgeon","offers":[{"title":"35W \/ 4200K \/ G12","offer_id":57268658274648,"sku":"4752280005614","price":35.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/1be87fbfd83b05a5e036d25d4cb84045a14e4f74.png?v=1778507760"},{"product_id":"thorgeon-monimetallilamppu-g12-70w-4200k","title":"Thorgeon metal halide lamp G12 70W 6000lm 4200K – HID, T6 tube","description":"\u003cp\u003eThe Thorgeon metal halide lamp is a professional-grade HID gas discharge lamp that produces 6,000 lumens of light output with a 4200 K neutral white color. The lower power model is suitable for advertising luminaires, pole and bollard lights, smaller retail lighting, and powerful floodlights for patios and yards. Requires an external HID ballast and ignitor — does not operate directly on mains voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG12 base. Requires an external HID ballast + ignitor. Warm-up time 1–4 minutes, re-ignition requires cooling.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp type: Metal halide lamp (HID, Metal Halide gas discharge lamp)\u003c\/li\u003e\n  \u003cli\u003eBrand: Thorgeon\u003c\/li\u003e\n  \u003cli\u003eBase: G12 (two-pin)\u003c\/li\u003e\n  \u003cli\u003ePower: 70 W\u003c\/li\u003e\n  \u003cli\u003eLamp operating voltage: 80–100 V (internal discharge voltage — not mains voltage)\u003c\/li\u003e\n  \u003cli\u003eLuminous flux: \u003cstrong\u003e6,000 lm\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor temperature: 4200 K (neutral white)\u003c\/li\u003e\n  \u003cli\u003eColor rendering index (CRI): 60–69\u003c\/li\u003e\n  \u003cli\u003eLuminous efficacy: 66.6 lm\/W\u003c\/li\u003e\n  \u003cli\u003eLamp shape: tubular, single-ended (clear glass)\u003c\/li\u003e\n  \u003cli\u003eLamp designation: T6 (diameter 22.5 mm)\u003c\/li\u003e\n  \u003cli\u003eExternal ballast required: Yes (HID ballast + ignitor)\u003c\/li\u003e\n  \u003cli\u003eDiameter: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003eOverall length: 90 mm\u003c\/li\u003e\n  \u003cli\u003eProduct code (EAN): 4752280005638\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and installation\u003c\/strong\u003e\u003c\/summary\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is a metal halide lamp?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide (MH) lamp is a gas discharge lamp that produces strong and consistent light by combining high-pressure mercury with metal halides. This gives the lamp:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh luminous efficacy\u003c\/strong\u003e — 6,000 lm from a single lamp even at lower power\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeutral color temperature\u003c\/strong\u003e — 4200 K (natural white)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral lighting color rendering\u003c\/strong\u003e — CRI 60–69 (suitable for general lighting, not for applications requiring precise color rendering)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact size\u003c\/strong\u003e — only Ø22.5 × 90 mm produces 6,000 lm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e70W vs 150W — when to choose lower power?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eLower power MH lamps are particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmaller stores\u003c\/strong\u003e — clothing stores, bookstores, small specialty shops\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvertising luminaires and floodlights\u003c\/strong\u003e — medium-sized light signs and building facades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePole and bollard lights\u003c\/strong\u003e — pole height 4–8 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmaller parking areas\u003c\/strong\u003e — local car parks (not large centers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance of older luminaires\u003c\/strong\u003e — when an existing system is designed for a 70W MH lamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need higher light output for a larger space, check out the \u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-150w-4200k\"\u003e150W model\u003c\/a\u003e (12,500 lm).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eExternal ballast and ignitor required\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis lamp \u003cstrong\u003edoes not operate directly on mains voltage\u003c\/strong\u003e — it requires an external HID ballast (choke) and ignitor. Important notes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThe internal voltage of the lamp is 80–100 V, not the same as the mains voltage (230 V)\u003c\/li\u003e\n  \u003cli\u003eThe ballast must be rated for a \u003cstrong\u003e70W metal halide lamp\u003c\/strong\u003e (not 150W or other power ratings)\u003c\/li\u003e\n  \u003cli\u003eAn ignitor is needed to start the lamp\u003c\/li\u003e\n  \u003cli\u003eInstallation requires the expertise of an electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompatible ballasts can be found in the \u003ca href=\"\/en\/collections\/liitantalaitteet-kuristimet\"\u003eElectrical Supplies → Ballasts\/Chokes\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarm-up time and cool-down\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe behavior of HID lamps differs from LED and fluorescent lamps:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarm-up time to full power:\u003c\/strong\u003e approx. 1–4 minutes after switching on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-ignition after power outage:\u003c\/strong\u003e requires 5–20 minutes of cooling — a hot lamp cannot be re-ignited immediately\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuring lifetime:\u003c\/strong\u003e color temperature may shift slightly and light level may decrease (typical HID phenomenon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eHID lamps are best suited for spaces where lighting is on for long periods and short on\/off cycles are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCRI 60–69 — for general lighting, not color accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe color rendering index (CRI 60–69) of this lamp is slightly lower than that of the 150W model (CRI 70–79). In practice, this means:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuitable for general lighting\u003c\/strong\u003e — parking areas, warehouses, outdoor lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor differences are not precisely distinguishable\u003c\/strong\u003e — e.g., the colors of clothes and jewelry may appear different compared to natural light\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNot suitable for retail lighting where color accuracy is important\u003c\/strong\u003e — clothing stores, jewelry stores, exhibition spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need better color rendering for retail lighting, consider the more powerful \u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-150w-4200k\"\u003e150W model (CRI 70–79)\u003c\/a\u003e or an LED alternative.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLED alternative — a long-term investment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMetal halide lamps are being phased out as LED technology develops. LED alternatives offer a longer lifespan (LED 50,000–100,000 h vs MH 6,000–15,000 h), lower energy consumption, instant full power, and no cool-down time for re-ignition. However, this Thorgeon metal halide lamp is suitable for maintaining existing HID systems and for applications where an LED replacement cannot yet be made.\u003c\/p\u003e\n\n\u003cp\u003eAlso check out our selection in the \u003ca href=\"\/en\/collections\/led-teollisuusvalaisimet\"\u003eLED industrial luminaires\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/valonheittimet\"\u003efloodlights\u003c\/a\u003e categories.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety notices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse the lamp only in a suitable enclosed luminaire — due to UV radiation, open installation can be dangerous\u003c\/li\u003e\n  \u003cli\u003eDo not touch a hot lamp\u003c\/li\u003e\n  \u003cli\u003eIf the lamp breaks, act carefully — it contains a small amount of mercury\u003c\/li\u003e\n  \u003cli\u003eAt the end of its life, recycle according to the WEEE directive at a WEEE collection point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eCheck that the luminaire has a G12 base and is designed for a 70W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eCheck that an external HID ballast and ignitor are used (\u003cstrong\u003e70W MH\u003c\/strong\u003e rated, not 150W)\u003c\/li\u003e\n  \u003cli\u003eTurn off the power at the main switch\u003c\/li\u003e\n  \u003cli\u003eInstall the lamp — do not touch the glass with your fingers (grease can cause a hot spot)\u003c\/li\u003e\n  \u003cli\u003eTurn on the power\u003c\/li\u003e\n  \u003cli\u003eWait 1–4 minutes to reach full power\u003c\/li\u003e\n  \u003cli\u003eCheck that the lamp burns steadily without flickering\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eAlso check out our range of \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003eother metal halide lamps\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Thorgeon","offers":[{"title":"70W \/ 4200K \/ G12","offer_id":57268704543064,"sku":"4752280005638","price":35.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/1be87fbfd83b05a5e036d25d4cb84045a14e4f74.png?v=1778507760"},{"product_id":"thorgeon-monimetallilamppu-g12-150w-3000k","title":"Thorgeon Metal Halide Lamp G12 150W 12500lm 3000K – HID, warm white","description":"\u003cp\u003eThe Thorgeon metal halide lamp is a professional-grade HID gas discharge lamp that produces an extremely powerful 12,500 lumen light output with a warm 3000K color temperature. The 3000K shade is rare in the metal halide lamp category – especially suitable for atmospheric lighting in large spaces, shops, restaurants, and lobbies. Requires an external HID ballast and ignitor – does not operate directly on mains voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG12 base. Requires an external HID ballast + ignitor. Warm-up time 1–4 minutes, restrike requires cooling.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"product-notice product-notice--warning\"\u003e\n  \u003cp\u003e\u003cstrong\u003e⚠ Order product\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eDelivery time approx. \u003cstrong\u003e2 weeks\u003c\/strong\u003e from order. Availability can be checked in the shopping cart.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp type: Metal Halide Lamp (HID, Metal Halide gas discharge lamp)\u003c\/li\u003e\n  \u003cli\u003eBrand: Thorgeon\u003c\/li\u003e\n  \u003cli\u003eBase: G12 (bi-pin)\u003c\/li\u003e\n  \u003cli\u003ePower: 150 W\u003c\/li\u003e\n  \u003cli\u003eLamp operating voltage: 80–100 V (internal discharge voltage – not mains voltage)\u003c\/li\u003e\n  \u003cli\u003eLuminous flux: \u003cstrong\u003e12,500 lm\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor temperature: \u003cstrong\u003e3000 K (warm white – rare in MH category)\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor rendering index (CRI): 70–79\u003c\/li\u003e\n  \u003cli\u003eLuminous efficacy: 83.3 lm\/W\u003c\/li\u003e\n  \u003cli\u003eLamp shape: tubular, single-ended (clear glass)\u003c\/li\u003e\n  \u003cli\u003eLamp designation: T6 (diameter 22.5 mm)\u003c\/li\u003e\n  \u003cli\u003eExternal ballast required: Yes (HID ballast + ignitor)\u003c\/li\u003e\n  \u003cli\u003eDiameter: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003eOverall length: 100 mm\u003c\/li\u003e\n  \u003cli\u003eProduct code (EAN): 4752280005645\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and Installation\u003c\/strong\u003e\u003c\/summary\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is a metal halide lamp?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide (MH) lamp is a gas discharge lamp that produces an extremely powerful and consistent light by combining high-pressure mercury with metal halides. This gives the lamp:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh light output\u003c\/strong\u003e — 12,500 lm from a single lamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarm color temperature\u003c\/strong\u003e — 3000 K (incandescent-like, rare in MH category)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModerate color rendering\u003c\/strong\u003e — CRI 70–79\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmall physical size\u003c\/strong\u003e — only Ø22.5 × 100 mm produces 12,500 lm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e3000K — a warm shade for large spaces\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMost metal halide lamps are produced with cooler shades (4000K, 4200K, 5000K, 6500K), as their gas discharge spectrum naturally produces cooler light. The 3000K warm white MH lamp is a \u003cstrong\u003especial product\u003c\/strong\u003e, especially suitable for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHotel and restaurant ambient lighting\u003c\/strong\u003e — large lobbies, restaurant halls, foyers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClothing stores and interior design shops\u003c\/strong\u003e — warm shades highlight products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJewelry stores\u003c\/strong\u003e — natural sparkle of gold and jewelry in warm light\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVintage atmosphere\u003c\/strong\u003e — in older spotlights where an incandescent-like shade is desired\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent venues and concert halls\u003c\/strong\u003e — warm ambient lighting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you need a cooler shade (e.g., for industrial, warehouse, sports field use), check out the \u003ca href=\"\/en\/products\/thorgeon-monimetallilamppu-g12-150w-4200k\"\u003e4200K model\u003c\/a\u003e or our selection of \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003eother metal halide lamps\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eExternal ballast and ignitor required\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis lamp \u003cstrong\u003edoes not operate directly on mains voltage\u003c\/strong\u003e — it requires an external HID ballast and ignitor. Important notes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThe internal lamp voltage is 80–100 V, not the same as mains voltage (230 V)\u003c\/li\u003e\n  \u003cli\u003eThe ballast must be rated for a 150W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eAn ignitor is required to start the lamp\u003c\/li\u003e\n  \u003cli\u003eInstallation requires the expertise of an electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompatible ballasts can be found in the \u003ca href=\"\/en\/collections\/liitantalaitteet-kuristimet\"\u003eElectrical Supplies → Ballasts\/Chokes\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarm-up time and restrike cooling\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe behavior of HID lamps differs from LED and fluorescent lamps:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarm-up time to full power:\u003c\/strong\u003e approximately 1–4 minutes after switching on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestrike after power outage:\u003c\/strong\u003e requires 5–20 minutes of cooling — a hot lamp cannot be re-ignited immediately\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuring lifetime:\u003c\/strong\u003e color temperature may shift slightly and light level may decrease (typical HID phenomenon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor this reason, HID lamps are best suited for spaces where lighting is on for long periods and short on\/off cycles are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLED alternative — a long-term investment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMetal halide lamps are being phased out as LED technology develops. LED alternatives offer a longer lifespan (LED 50,000–100,000 h vs MH 6,000–15,000 h), lower energy consumption (LED 150–200 lm\/W vs MH 83 lm\/W), instant full power, and no cooling time for restrike.\u003c\/p\u003e\n\n\u003cp\u003eHowever, this Thorgeon metal halide lamp is suitable for maintaining existing HID systems and for applications where LED conversion is not yet possible. Also, explore our selection in the \u003ca href=\"\/en\/collections\/led-teollisuusvalaisimet\"\u003eLED Industrial Luminaires\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety notices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse the lamp only in a suitable enclosed luminaire — open installation can be dangerous due to UV radiation\u003c\/li\u003e\n  \u003cli\u003eDo not touch a hot lamp\u003c\/li\u003e\n  \u003cli\u003eIf the lamp breaks, proceed with caution — it contains a small amount of mercury\u003c\/li\u003e\n  \u003cli\u003eAt the end of its life, recycle according to the WEEE directive at an electrical and electronic equipment collection point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eCheck that the luminaire has a G12 base and is designed for a 150W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eCheck that an external HID ballast and ignitor are used (150W MH rating)\u003c\/li\u003e\n  \u003cli\u003eTurn off the power at the main switch\u003c\/li\u003e\n  \u003cli\u003eInstall the lamp — do not touch the glass with your fingers (grease can cause a hot spot)\u003c\/li\u003e\n  \u003cli\u003eTurn on the power\u003c\/li\u003e\n  \u003cli\u003eWait 1–4 minutes to reach full power\u003c\/li\u003e\n  \u003cli\u003eCheck that the lamp is burning steadily without flickering\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eAlso, explore our selection of \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003eother metal halide lamps\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Thorgeon","offers":[{"title":"150W \/ 3000K \/ Grade 12","offer_id":57268751728984,"sku":"4752280005645","price":39.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/1be87fbfd83b05a5e036d25d4cb84045a14e4f74.png?v=1778507760"},{"product_id":"thorgeon-monimetallilamppu-g12-150w-4200k","title":"Thorgeon metal halide lamp G12 150W 12500lm 4200K – HID, T6 tube","description":"\u003cp\u003eThe Thorgeon metal halide lamp is a professional-grade HID gas discharge lamp that produces an extremely powerful light output of 12,500 lumens with a neutral white shade of 4200 K. Suitable for shop lighting, exhibition spaces, sports halls, large lobbies, and general lighting in industrial halls. Requires an external HID ballast and ignitor — does not operate directly on mains voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eG12 base. Requires an external HID ballast + ignitor. Ignition time 1–4 minutes, re-ignition requires cooling.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"product-notice product-notice--warning\"\u003e\n  \u003cp\u003e\u003cstrong\u003e⚠ Order product\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eDelivery time approximately \u003cstrong\u003e2 weeks\u003c\/strong\u003e from order. Availability can be checked in the shopping cart.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp type: Metal halide lamp (HID, Metal Halide gas discharge lamp)\u003c\/li\u003e\n  \u003cli\u003eBrand: Thorgeon\u003c\/li\u003e\n  \u003cli\u003eBase: G12 (bi-pin)\u003c\/li\u003e\n  \u003cli\u003ePower: 150 W\u003c\/li\u003e\n  \u003cli\u003eLamp operating voltage: 80–100 V (internal discharge voltage — not mains voltage)\u003c\/li\u003e\n  \u003cli\u003eLuminous flux: \u003cstrong\u003e12,500 lm\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eColor temperature: 4200 K (neutral white)\u003c\/li\u003e\n  \u003cli\u003eColor rendering index (CRI): 70–79\u003c\/li\u003e\n  \u003cli\u003eLuminous efficacy: 83.3 lm\/W\u003c\/li\u003e\n  \u003cli\u003eLamp shape: tubular, single-ended (clear glass)\u003c\/li\u003e\n  \u003cli\u003eLamp designation: T6 (diameter 22.5 mm)\u003c\/li\u003e\n  \u003cli\u003eExternal ballast required: Yes (HID ballast + ignitor)\u003c\/li\u003e\n  \u003cli\u003eDiameter: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003eOverall length: 100 mm\u003c\/li\u003e\n  \u003cli\u003eProduct code (EAN): 4752280005652\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eCompatibility and installation\u003c\/strong\u003e\u003c\/summary\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is a metal halide lamp?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA metal halide lamp (MH) is a gas-discharge lamp that produces extremely strong and uniform light by combining high-pressure mercury with metal halides. This gives the lamp:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh luminous efficacy\u003c\/strong\u003e — 12,500 lm from a single lamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeutral color temperature\u003c\/strong\u003e — 4200 K (natural white)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModerate color rendering\u003c\/strong\u003e — CRI 70–79\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmall physical size\u003c\/strong\u003e — only Ø22.5 × 100 mm produces 12,500 lm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eExternal ballast and ignitor required\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis lamp \u003cstrong\u003edoes not operate directly on mains voltage\u003c\/strong\u003e — it requires an external HID ballast and ignitor. Important notes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThe internal lamp voltage is 80–100 V, not the same as mains voltage (230 V)\u003c\/li\u003e\n  \u003cli\u003eThe ballast must be rated for a 150W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eAn ignitor is required to start the lamp\u003c\/li\u003e\n  \u003cli\u003eInstallation requires the expertise of an electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompatible ballasts can be found in the \u003ca href=\"\/en\/collections\/liitantalaitteet-kuristimet\"\u003eElectrical Supplies → Ballasts\/Chokes\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIgnition time and re-cooling\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe behavior of HID lamps differs from LED and fluorescent lamps:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition time to full power:\u003c\/strong\u003e approximately 1–4 minutes after switching on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-ignition after power outage:\u003c\/strong\u003e requires 5–20 minutes of cooling — a hot lamp cannot be reignited immediately\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuring lifetime:\u003c\/strong\u003e color temperature may shift slightly and light level may decrease (typical HID phenomenon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor this reason, HID lamps are best suited for spaces where lighting is on for long periods and short on\/off cycles are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetail lighting\u003c\/strong\u003e — clothing stores, jewelry shops, exhibition spaces\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor advertising luminaires\u003c\/strong\u003e — large billboards, facades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSports fields and indoor sports halls\u003c\/strong\u003e — general lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParking areas and multi-story car parks\u003c\/strong\u003e — high floodlights\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLobbies and concert venues\u003c\/strong\u003e — event lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial halls and warehouses\u003c\/strong\u003e — general lighting with high ceilings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLED alternative — a long-term investment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMetal halide lamps are being phased out of the market as LED technology develops. LED alternatives offer:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLonger lifespan (LED 50,000–100,000 h vs MH 6,000–15,000 h)\u003c\/li\u003e\n  \u003cli\u003eLower energy consumption (LED 150–200 lm\/W vs MH 83 lm\/W)\u003c\/li\u003e\n  \u003cli\u003eInstant full power (no ignition time)\u003c\/li\u003e\n  \u003cli\u003eNo cooling time for re-ignition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eHowever, this Thorgeon metal halide lamp is suitable for maintaining existing HID systems and for applications where LED conversion is not yet possible. Also, explore our selection in the \u003ca href=\"\/en\/collections\/led-teollisuusvalaisimet\"\u003eLED Industrial Lights\u003c\/a\u003e category.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse the lamp only in a suitable enclosed fixture — due to UV radiation, open installation can be dangerous\u003c\/li\u003e\n  \u003cli\u003eDo not touch a hot lamp\u003c\/li\u003e\n  \u003cli\u003eIf the lamp breaks, proceed with caution — contains a small amount of mercury\u003c\/li\u003e\n  \u003cli\u003eAt the end of its life, recycle according to the WEEE directive at a WEEE collection point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eCheck that the luminaire has a G12 base and is designed for a 150W metal halide lamp\u003c\/li\u003e\n  \u003cli\u003eCheck that an external HID ballast and ignitor are used (150W MH rating)\u003c\/li\u003e\n  \u003cli\u003eTurn off power at the main switch\u003c\/li\u003e\n  \u003cli\u003eInstall the lamp — do not touch the glass with fingers (grease can cause a hot spot)\u003c\/li\u003e\n  \u003cli\u003eTurn on the power\u003c\/li\u003e\n  \u003cli\u003eWait 1–4 minutes for full power to be achieved\u003c\/li\u003e\n  \u003cli\u003eCheck that the lamp glows steadily without flickering\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eAlso, explore our selection of \u003ca href=\"\/en\/collections\/monimetallilamput\"\u003eother metal halide lamps\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Thorgeon","offers":[{"title":"150W \/ 4200K \/ G12","offer_id":57268777156952,"sku":"4752280005652","price":39.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/files\/1be87fbfd83b05a5e036d25d4cb84045a14e4f74.png?v=1778507760"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0577\/2171\/6917\/collections\/images_4.jpg?v=1758041790","url":"https:\/\/lomenled.com\/en\/collections\/g12-lamps.oembed","provider":"Lumenled Oy","version":"1.0","type":"link"}